• Marine Electric Fire Monitors Fire Fighting Water Foam Monitor
  • Marine Electric Fire Monitors Fire Fighting Water Foam Monitor
  • Marine Electric Fire Monitors Fire Fighting Water Foam Monitor
  • Marine Electric Fire Monitors Fire Fighting Water Foam Monitor
  • Marine Electric Fire Monitors Fire Fighting Water Foam Monitor
  • Marine Electric Fire Monitors Fire Fighting Water Foam Monitor

Marine Electric Fire Monitors Fire Fighting Water Foam Monitor

Water Form: Multiple Use Water Cannon
Material: Stainless Steel
Pressure Range: Medium-Pressure Water Gun
DC Gun Type: Switching DC Gun
Multiple Use Water Cannon Type: Spray Mist Jets
Jet: Jet / Fog
Samples:
US$ 1500/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
Marine Fire Fighting Water Foam Monitor
Fire Monitor Capacity
160-3600m3/H
Control Method
Manual/ Electric Monitor
Monitor Material
Stainless Steel 304 /316
Horizomtal
360c Rotation
Power Supply
380V, 50Hz, 3phase/ 440V, 60Hz, 3phase
Color
Red
Medium
Seawater, Afff Foams, Freshwater
Warranty
12 Months
Transport Package
Plywood
Specification
CCS EC
Trademark
GR
Origin
China
HS Code
8900021210
Production Capacity
10sets/Month

Product Description

Marine Electric Fire Monitors Fire Fighting Water Foam Monitor

CCS/BV Certification
Fire Monitor Capacity: 100-2400m3/h
Fire Pump: 4 Cycle, 8 Cylinder, 24VDC
Cummins Diesel engine

Electric Water Monitor
Marine Electric Fire Monitors Fire Fighting Water Foam Monitor

Manual Water Monitor
Marine Electric Fire Monitors Fire Fighting Water Foam Monitor


Introductions:
1. Firefighting equipment Approval: ABS, CCS, BV, DNV etc
2. Fire fighting equipment material: Stainless steel
3. Capacity of fire monitor/fire pump: 160m3/h, 180m3/h, 360m3/h, 600m3/h, 900m3/h, 1200m3/h, 3600m3/h, etc
4. Firefighting equipment Type: Supply external Fire Fighting Systems, FiFi1/4, FiFi1/2, FiFi 1, FiFi 2, etc
5. Fire Fighting System Engine: Cummins Engine or the demands you need
6. Fire fighting equipment Include: Fire pump, fire monitor, with Cummins Engine
7. Firefighting equipment color: Red

FIFI System
1. FiFi Class 2 System 7200m3/h
Diesel Engine Driven
Fire Pumps: 2X3600m3/h
Fire Monitors: 4X1800m3/h@150m,
Remote Control System

2. FiFi Class 1 System 2400m3/h
Diesel Engine Drivenor Electric Motor Driven
Fire Pumps: 2X1200m3/h or one 2400m3/h
Fire Monitors: 2X1200m3/h@120m
Remote Control System

3...FiFi 1/2 System
Diesel Engine Driven or Electric Motor Driven
Fire pumps: 1200m3/h
Fire Monitors: 2X600m3/h@120m or 1X1200m3/h@120m
Remote Control System

4. None Classed Fi-Fi System
Diesel Engine Drivenor Electric Motor Driven
Fire pumps: 2X300m3/h@145m
Fire Monitors: 2X300m3/h@85m

5. None Classed Fi-Fi System
6. Fire Pump Unit, fire pump Capacity: 4200m3/h, 3600 m3/h, 2400 m 3/h, 1800 m3/h, 1200 m3/h, 600 m3/h, 300 m3/h, 250 m3/h, ect
Certificate: CCS BV ABS DNV and other Class
7. Fire monitor
Including fire water monitor, foam monitor, powder monitor with Electric/hydraulic romote control and hand whell
Marine Electric Fire Monitors Fire Fighting Water Foam Monitor

Remark: Designated the best solution for you, according to your requirements. Above just for yr guidence.
If you need this products For ship, pls provide the below information for external Fire Fighting Systems
1. Capacity of the Fire monitor for this Fire Fighting Systems (m3/h)
2. Fire pump Capacity for Fire Fighting Systems(m3/h)
3. Need the diesel Engine for fire pump
4. Any special brand demands for diesel fire pump engine


Specification of External FIFI  System
Class
Notation
FiFi1 FiFi2 FiFi3
No. of
Monitors
2  
2


 
3 4 3 4
Monitor
capacity
(m3/h)
1200 3600 2400 1800 3200 2400/
2500
No. of
Pumps
1-2 2 2-4 2 2-4
Total
pump
capacity
(m3/h)
2400 7200 7200 9600 9600/
10000
Throw
length
(m)
120 180
(from bow)
150 180
(From bow)
150
Throw height (m) 45 110 at 70m 70 110 at 70m  

Certification
Marine Electric Fire Monitors Fire Fighting Water Foam Monitor



Welcome to contact us talk about details if you are interested in Marine Electric Fire Monitors Fire Fighting Water Foam Monitor,  Fire Pump or External FIFI Systems.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now