30 Person Imo Approved Marine Sewage Treatment Plant
CCS/EC approval
Standard: MEPC.227(64)
water recovery after treatment
Good quality
Competitive Price
Short delivery time
Marine Sewage Treatment Equipment
After waste water disposal,may water recovery
The SWCM type marine sewage treatment equipment uses activated sludge, contact oxidizing and principle of biologic membrane to digest the organic pollutant, which can treat sewage effectively and reach at the IMO new effluent standard or other stricter requirements.
The device is patent product, provided with independent innovation intellectual property.
1 Description
This plant is applicable to treat the sewage, which means human body wastes and the wastes from the toilets on vessels and which is also called "black water", to meet the effluent standards of IMO MEPC.227(64), and discharge the effluent to overboard. It is also applicable to treat galley & shower drainage which is called "grey water" on condition that the "grey water" should be pretreated and should select a bigger capacity model to match with.
Marine Sewage Treatment Plant belongs to the key devices for prevention of pollution form ships in seas and oceans according to the revised Annex IV of the International Convention of the Prevention of Pollution (MARPOL 73/78).
2 Main parameters
(1) Usage : it is used for treating teh sewage on board , shipyard or dock
(2) international standard :
IMO resolution IMO. MEPC.227(64) ,
Annex IV of (MARPOL 73/78) ,
MEPC.2(VI)
(3) discharge standard : TSS ≤ 35mg/L , BOD5 ≤ 25mg/L , COD ≤ 125mg/L , Coliform ≤ 100pc/100ml , PH: 6~8.5
(4)Electricity : AC380v. 50HZ, 3ΦAC440V , 60HZ, 3Φ (the electricity can be changed in according to your requirment )
(5)Capacity : from 15 persons to 440 persons
(6)Certificate : EC , CCS ,BV,GL,LR
|
IMO
Old standard |
IMO
New standard |
USCG |
Alaska |
TSS (mg/l) |
50 |
35 |
150 |
30 |
BOD5 (mg/l) |
50 |
25 |
NR |
30 |
COD (mg/l) |
NR |
125 |
NR |
NR |
coliform (per 100ml) |
250 |
100 |
200 |
20 |
PH |
6~9 |
6~8.5 |
NR |
6~9 |
Residual chlorine (mg/l) |
NR |
<0.5 |
NR |
10 |
Duration of type approval test (days) |
10 |
10 |
10 |
30 |
Ceritifcate
Oil water separator
Contact us