Customization: | Available |
---|---|
Throw Length: | 85m~150m (at 10 Bar) External Fifi System |
Throw Height: | 45m~70m External Fifi System |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Equipment | The basic requirement for FI-FI System | |||||
FIFI 1/4 | FIFI 1/2 | FIFI I | FIFI II | FIFI III | ||
Min.Number of Fire Monitor | 2 | 2 | 2 | 3 | 4 | 4 |
Min.jet rate of Fire Monitor(m3/h) | 300 | 600 | 1200 | 2400 | 1800 | 2400 |
Min.Number of Fire Pump | 1 | 1 | 1 | 2 | 2 | |
Min.Capacity of Fire Pump (m3/h) | 600 | 1200 | 2400 | 7200 | 9600 | |
Minimum height of jet trajectory above water surface (m) | 45 | 70 | 70 | |||
Min.Range(m) | 120 | 150 | 150 | |||
Minimum fuel holding time required for simultaneous and continuous operation of all Fire Monitors (H) | - | - | 24 | 96 | 96 | |
Min.Number of Foam Monitor | - | - | - | - | 2 | |
Min.jet rate of Foam Monitor (m3/h) | - | - | - | - | 300 | |
Continuous foaming time(min) | - | - | - | - | 30 | |
Min. foam supply rate (m3/min) | - | - | - | 100 |
|
|
Continuous foaming time(min) | - | - | - | 30 | 30 | |
Number of interface /Fire hose hydrant on each side of the ship |
- | - | 4 | 8 | 8 | |
Fireman's equipment | - | - | 4 | 8 | 8 |
Containerized FIFI System Unit