Model | Effective Flow Rate(m3/h) | Effective Flow Rate(m3/h) | Rated working presure | Entrance access |
1 | 480-1200 | 28.8-72 | 0.8 | DN50 |
2 | 1200-1500 | 72-90 | 0.8 | DN50 |
3 | 1500-1800 | 90-108 | 0.8 | DN50 |
4 | 1800-2400 | 108-144 | 0.8 | DN65 |
5 | 2400-3000 | 144-180 | 0.8 | DN80 |
6 | 3000-3600 | 180-216 | 1 | DN80 |
7 | 3600-4000 | 216-240 | 1 | DN80 |
8 | 4000-4800 | 240-288 | 1 | DN100 |
9 | 4800-6000 | 288-360 | 1.2 | DN100 |
10 | 6000-7200 | 360-432 | 1.2 | DN150 |
11 | 7200-9000 | 432-540 | 1.4 | DN150 |
12 | 9000-10800 | 540-648 | 1.4 | DN150 |
13 | 10800-18000 | 648-1080 | 1.4 | DN150 |
14 | 18000-26000 | 1080-1560 | 1.4 | DN200 |
15 | 26000-32000 | 1560-1920 | 1.4 | DN250 |
16 | 32000-60000 | 1920-3600 | 1.4 | DN300 |
17 | 60000-80000 | 3600-4800 | 1.4 | DN400 |
Pump Inlet | Pump Outlet | Flow(m3/h) | Range(m) | Speed(rpm) | Institutional form |
150 | 125 | 120-180 | 120 | 2950 | Vertical electric |
200 | 150 | 160-400 | 120-145 | 2960 | End inlet top outlet |
250 | 200 | 400-720 | 120-150 | 1800/1450 | End inlet top outlet |
250 | 200 | 400-900 | 120-145 | 1800 | Side inlet top outlet |
300 | 250 | 1000-1800 | 120-160 | 1800 | End inlet top outlet/Side inlet top outlet Bottom inlet top outlet Side inlet side outlet |
350 | 250 | 1200-2000 | 110-150 | 1800 | Ende inlet top outlet |
400 | 350 | 1500-2800 | 120-175 | 1800 | Side inlet top outlet Bottom inlet top outlet |
450 | 350 | 1800-3600 | 120-165 | 1300 | End inlet top outlet |
500 | 400 | 2600-4300 | 120-150 | 1000 | Side inlet top outlet |
550 | 450 | 3000-4800 | 120-150 | 1000 | Side inlet side outlet |
600 | 500 | 3600-6600 | 120-150 | 1000 | Side inlet top outlet |
Equipment | The basic requirement for FI-FI System | |||||
FIFI 1/4 | FIFI 1/2 | FIFI I | FIFI II | FIFI III | ||
Min.Number of Fire Monitor | 2 | 2 | 2 | 3 | 4 | 4 |
Min.jet rate of Fire Monitor(m3/h) | 300 | 600 | 1200 | 2400 | 1800 | 2400 |
Min.Number of Fire Pump | 1 | 1 | 1 | 2 | 2 | |
Min.Capacity of Fire Pump (m3/h) | 600 | 1200 | 2400 | 7200 | 9600 | |
Performance of Fire Monitor | - | - | - | - | - | |
Minimum height of jet trajectory above water surface (m) | 45 | 70 | 70 | |||
Min.Range(m) | 120 | 150 | 150 | |||
Minimum fuel holding time required for simultaneous and continuous operation of all Fire Monitors (H) | - | - | 24 | 96 | 96 | |
Fixed Foam System: | - | - | - | - | - | |
Min.Number of Foam Monitor | - | - | - | - | 2 | |
Min.jet rate of Foam Monitor (m3/h) | - | - | - | - | 300 | |
Continuous foaming time(min) | - | - | - | - | 30 | |
Mobile fire fighting equipment: | - | - | - | - | - | |
Mobile foam generator | - | - | - | - | - | |
Min. foam supply rate (m3/min) | - | - | - | 100 |
|
|
Continuous foaming time(min) | - | - | - | 30 | 30 | |
Fire hose | - | - | - | - | - | |
Number of interface /Fire hose hydrant on each side of the ship |
- | - | 4 | 8 | 8 | |
Fireman's equipment | - | - | 4 | 8 | 8 |