The main fire pumps installed on ships are located inside the ship's engine room, usually at the bottom platform. They are electrically driven from the main supply of the ship.
It is very common to find them installed near general service pump and ballast pumps. The general service pump lines are interconnected with the fire main and at times are used to provide water to the fire system
Model | Effective Flow Rate(m3/h) | Effective Flow Rate(m3/h) | Rated working presure | Entrance access |
1 | 480-1200 | 28.8-72 | 0.8 | DN50 |
2 | 1200-1500 | 72-90 | 0.8 | DN50 |
3 | 1500-1800 | 90-108 | 0.8 | DN50 |
4 | 1800-2400 | 108-144 | 0.8 | DN65 |
5 | 2400-3000 | 144-180 | 0.8 | DN80 |
6 | 3000-3600 | 180-216 | 1 | DN80 |
7 | 3600-4000 | 216-240 | 1 | DN80 |
8 | 4000-4800 | 240-288 | 1 | DN100 |
9 | 4800-6000 | 288-360 | 1.2 | DN100 |
10 | 6000-7200 | 360-432 | 1.2 | DN150 |
11 | 7200-9000 | 432-540 | 1.4 | DN150 |
12 | 9000-10800 | 540-648 | 1.4 | DN150 |
13 | 10800-18000 | 648-1080 | 1.4 | DN150 |
14 | 18000-26000 | 1080-1560 | 1.4 | DN200 |
15 | 26000-32000 | 1560-1920 | 1.4 | DN250 |
16 | 32000-60000 | 1920-3600 | 1.4 | DN300 |
17 | 60000-80000 | 3600-4800 | 1.4 | DN400 |
Pump Inlet | Pump Outlet | Flow(m3/h) | Range(m) | Speed(rpm) | Institutional form |
150 | 125 | 120-180 | 120 | 2950 | Vertical electric |
200 | 150 | 160-400 | 120-145 | 2960 | End inlet top outlet |
250 | 200 | 400-720 | 120-150 | 1800/1450 | End inlet top outlet |
250 | 200 | 400-900 | 120-145 | 1800 | Side inlet top outlet |
300 | 250 | 1000-1800 | 120-160 | 1800 | End inlet top outlet/Side inlet top outlet Bottom inlet top outlet Side inlet side outlet |
350 | 250 | 1200-2000 | 110-150 | 1800 | Ende inlet top outlet |
400 | 350 | 1500-2800 | 120-175 | 1800 | Side inlet top outlet Bottom inlet top outlet |
450 | 350 | 1800-3600 | 120-165 | 1300 | End inlet top outlet |
500 | 400 | 2600-4300 | 120-150 | 1000 | Side inlet top outlet |
550 | 450 | 3000-4800 | 120-150 | 1000 | Side inlet side outlet |
600 | 500 | 3600-6600 | 120-150 | 1000 | Side inlet top outlet |
Equipment | The basic requirement for FI-FI System | |||||
FIFI 1/4 | FIFI 1/2 | FIFI I | FIFI II | FIFI III | ||
Min.Number of Fire Monitor | 2 | 2 | 2 | 3 | 4 | 4 |
Min.jet rate of Fire Monitor(m3/h) | 300 | 600 | 1200 | 2400 | 1800 | 2400 |
Min.Number of Fire Pump | 1 | 1 | 1 | 2 | 2 | |
Min.Capacity of Fire Pump (m3/h) | 600 | 1200 | 2400 | 7200 | 9600 | |
Performance of Fire Monitor | - | - | - | - | - | |
Minimum height of jet trajectory above water surface (m) | 45 | 70 | 70 | |||
Min.Range(m) | 120 | 150 | 150 | |||
Minimum fuel holding time required for simultaneous and continuous operation of all Fire Monitors (H) | - | - | 24 | 96 | 96 | |
Fixed Foam System: | - | - | - | - | - | |
Min.Number of Foam Monitor | - | - | - | - | 2 | |
Min.jet rate of Foam Monitor (m3/h) | - | - | - | - | 300 | |
Continuous foaming time(min) | - | - | - | - | 30 | |
Mobile fire fighting equipment: | - | - | - | - | - | |
Mobile foam generator | - | - | - | - | - | |
Min. foam supply rate (m3/min) | - | - | - | 100 |
|
|
Continuous foaming time(min) | - | - | - | 30 | 30 | |
Fire hose | - | - | - | - | - | |
Number of interface /Fire hose hydrant on each side of the ship |
- | - | 4 | 8 | 8 | |
Fireman's equipment | - | - | 4 | 8 | 8 |
Location description
Marine/Land Fire Fighting Module