Marine Fire Pump for External Fire Fighting Fifi System High Pressure Output with CCS BV Certificate

Product Details
Customization: Available
Npshr: 5.8m
Speed: 1800rpm Fire Pumps
Manufacturer/Factory, Trading Company
Gold Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001
OEM/ODM Availability
Yes
  • Marine Fire Pump for External Fire Fighting Fifi System High Pressure Output with CCS BV Certificate
  • Marine Fire Pump for External Fire Fighting Fifi System High Pressure Output with CCS BV Certificate
  • Marine Fire Pump for External Fire Fighting Fifi System High Pressure Output with CCS BV Certificate
  • Marine Fire Pump for External Fire Fighting Fifi System High Pressure Output with CCS BV Certificate
  • Marine Fire Pump for External Fire Fighting Fifi System High Pressure Output with CCS BV Certificate
  • Marine Fire Pump for External Fire Fighting Fifi System High Pressure Output with CCS BV Certificate
Find Similar Products

Basic Info.

Model NO.
Fire water pump
MOQ
2 Set
Fire Fighting System Material
Cast Iron
Certificate
CCS, BV
Place of Origin
China (Mainland)
Model Number
Fifi System
Firefighting Equipment Type
Fifi1/4, Fifi1/2, Fifi 1, Fifi 2, etc.
Fire Fighting System Parts
Fire Pump, Fire Monitor, with Diesel Engine
Usage
for Marine Fire Fighting
Transport Package
Wooden Case
Specification
CCS/BV
Origin
China
Production Capacity
300 Set/Sets Per Year

Product Description


Marine Fire Pump for External Fire Fighting Fifi System High Pressure Output with CCS BV Certificate
Marine Fire Pump for External Fire Fighting FIFI System
High Pressure Output with CCS BV Certificate

 
-------------------
Introductions:

1.Firefighting equipment Approval : CCS,BV
2.Fire fighting equipment material : Cast Iron
3.Capacity of fire monitor/fire pump : 160m3/h,180m3/h ,360m3/h ,600m3/h , 900m3/h , 1200m3/h , 3600m3/h ,etc
4.Fire fighting equipment Type : Supply external Fire Fighting Systems , FiFi1/4,FiFi1/2, FiFi 1, FiFi 2 ,
5.Fire Fighting System Engine : Cummins Engine or the demands you need
6.Fire fighting equipment Include : Fire pump,fire monitor,with Cummins Engine
7.Firefighting equipment color : Red
Marine Fire Pump for External Fire Fighting Fifi System High Pressure Output with CCS BV Certificate
Marine Fire Pump for External Fire Fighting Fifi System High Pressure Output with CCS BV Certificate
Marine Fire Pump for External Fire Fighting Fifi System High Pressure Output with CCS BV Certificate

---------------------------------------------------------------------
Double-suction pumps VS Single-suction pumps


Difference 1: The flow rate is different.
The single-suction pump has a small flow rate, while the double-suction pump has a large flow rate.

Difference 2: The structure is different.
A single-suction pump means that there is only one impeller in the pump, and single-suction means that water is sucked from one side of the impeller. A double-suction pump consists of two impellers placed back to back, with water flowing from the impellers into a volute.

Difference 3: Different application scenarios.
Single suction pumps are the most common type of water pump used in agriculture. Double-suction pumps are mostly used for water supply and drainage in mines, cities, power stations, and various water conservancy projects.
Marine Fire Pump for External Fire Fighting Fifi System High Pressure Output with CCS BV Certificate
Marine Fire Pump for External Fire Fighting Fifi System High Pressure Output with CCS BV Certificate
Marine Fire Pump for External Fire Fighting Fifi System High Pressure Output with CCS BV Certificate

-------------------------------------------------------------------------
Technical Parameters for Firefighting Class System

Class Notation

FiFi1

FiFi2

FiFi3

No. of Monitors

2

 2

3

4

3

4

Monitor capacity (m3/h)

1200

3600

2400

1800

3200

2400/2500

No. of Pumps

1-2

2

2-4

2

2-4

Total pump capacity (m3/h)

2400

7200

7200

9600

9600/
10000

Throw length (m)

120

180
(From bow)

150

180
(From bow)

150

Throw height (m)

45

110 at 70m

70

110 at 70m

 
 
Within a fire sprinkler system, a fire pump plays a crucial role in enhancing the system's effectiveness.

Operating on electricity or diesel power, the fire pump generates high pressure, facilitating the distribution of water through the sprinkler system and hose risers. This pressure ensures rapid and efficient fire suppression, a critical aspect of fire safety protocols.

 
Marine Fire Pump for External Fire Fighting Fifi System High Pressure Output with CCS BV Certificate
Marine Fire Pump for External Fire Fighting Fifi System High Pressure Output with CCS BV Certificate
Marine Fire Pump for External Fire Fighting Fifi System High Pressure Output with CCS BV Certificate


Remark:
Designated the best solution for you,according to your requirements. Above just for yr guidence.
If you need this products For ship,pls provide the below information for external Fire Fighting Systems
1. Capacity of the Fire monitor for this Fire Fighting Systems (m3/h)
2. Fire pump Capacity for Fire Fighting Systems(m3/h)
3.Need the diesel Engine for fire pump
4.Any special brand demands for diesel fire pump engine

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier