Decompression: Normal Fire Hydrant
Rotation: Ordinary Bolt
Outdoor Fire Hydrant Type: High-Pressure Fire Hydrant
Fire Hydrant Type: Ordinary
Type: Fire Pump
Fire Pump Certificate: CCS, BV
Samples:
US$ 5000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
Diesel Engine Driven Fire Fightin Pump Set
Capacity
150~3600m3/H Fire Fighting Pump
Total Head(M)
130 - 160
Power(Kw)
145 - 726
Speed(R/Min)
1800 - 2960
Fire Pump Shaft
Stainless Steel
Shaft Sealing
Soft Sealing
Fire Pump Medium
Seawater
Fire Pump Material
Stainless Steel
Transport Package
Plywood Case
Specification
SOLAS
Trademark
GR
Origin
China
Production Capacity
100sets /Year

Product Description

Diesel Engine Driven Fire Fighting Pump Set for External FIFI System
 

Description

The main fire pumps installed on ships are located inside the ship's engine room, usually at the bottom platform. They are electrically driven from the main supply of the ship.

It is very common to find them installed near general service pump and ballast pumps. The general service pump lines are interconnected with the fire main and at times are used to provide water to the fire system
 

Capacity &  Requirements

  • Emergency fire pump to be provided in Passenger ships of 1000 grt and above 
  • Emergency fire pump to be provided in cargo ships of 2000 grt and above
  • The emergency fire pump must be driven by a self-cooled compression ignition engine or by an electric motor powered from an emergency generator
  • It must be located outside the machinery space, in a compartment not forming the part of the engine room
  • The emergency fire pump must be provided with its independent suction arrangement and the total suction head should not exceed 4.5 meters under all conditions of list or trim
  • The emergency fire pump capacity to be at least 25m3/hr delivering two ½ inches bore jet of water having a horizontal throw not less than 40 ft
  • If the pump is located above the water level, a priming arrangement must be provided to fill the pump casing with water before starting
  • In a motor-driven emergency fire pump, a heating arrangement must be provided which is also supplied from the emergency switchboard power
  • For engine driven pump, the fuel tank capacity should be such that the engine can run the pump at its full load for at least 3 hrs
  • A separate reserve fuel tank to be provided outside the engine room machinery space
  • The prime mover engine should be of manual/ battery/ hydraulic start type which can be started and operated by one man

Diesel Engine Driven Fire Fighting Pump Set for External Fifi System



Introductions Of Marine External Fire Fighting FiFi System

1. Fire fighting FiFi System Approval: ABS, CCS, BV, DNV etc
2. Fire fighting FiFi System material: Stainless steel
3. Capacity of fire monitor/fire pump: 160m3/h, 180m3/h, 360m3/h, 600m3/h, 900m3/h, 1200m3/h, 3600m3/h, etc
4. Firefighting equipment Type: Supply external Fire Fighting Systems, FiFi1/4, FiFi1/2, FiFi 1, FiFi 2, etc
5. Fire Fighting System Engine: Cummins Engine or the demands you need
6. Fire fighting FiFi System Includes: Fire pump, fire monitor, with Cummins Engine, Hydraulic power pack optional

Specification of Fire Pump
Model Capacity(m³/h) Total Head(m) Power(Kw) Speed(r/min)
CXB200-150-A 300 145 145 2960
CXB200-150-B 300 300 350 2100
CXB200-150-00D 350 130 174 1800
CXB250-200-A 600 130 320 2960
CXB250-200-B 600 150 345 1450
CXB250-200-B 600 300 654 2100
CXB250-200-00D 600 130 345 1800
CXB300-250-A 1200 140 586 1800
CXB300-250-B 1200 140 563 1800
CXB300-250-C 1200 160 668 1800
CXB300-250-D 1200 160 726 1800
CXB300-250-00D 1600/1200 130/140 708/586 1800/1800
 
Detailed image of Fire Pump

Diesel Engine Driven Fire Fighting Pump Set for External Fifi System

Diesel Engine Driven Fire Fighting Pump Set for External Fifi System

Diesel Engine Driven Fire Fighting Pump Set for External Fifi System
 

Company information


Diesel Engine Driven Fire Fighting Pump Set for External Fifi System


Chongqing Gathering Marine Equipment Co,.Ltd founded in 2007, specializes in supplying a broad range of marine and occupational safety items. We has advanced and grown to become a leading supplier of approved and certified safety equipment to business partners worldwide. We are dedicated to achieving customer satisfaction by supplying quality products of competitive prices, backed up by superior service. Our products are SOLAS compliant (where applicable), approved by the administrations of contracting governments, and certified in accordance with MED, resp.CCS, EC, USCG,or NKK stipulations.

External FIFI System


Diesel Engine Driven Fire Fighting Pump Set for External Fifi System


Containerized FIFI System


Diesel Engine Driven Fire Fighting Pump Set for External Fifi System


Our Certification


Diesel Engine Driven Fire Fighting Pump Set for External Fifi System


Contact us
Welcome to contact us talk about details if you are interested in Diesel Engine Driven Fire Fighting Pump Set , External FIFI System, Containerized FIFI System Unit or other fire fighting products.


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now